HomeNEBNext® Ultra™ II RNA Library Prep Kit for Illumina®
NEBNext® Ultra™ II RNA Library Prep Kit for Illumina®
Note that Sample Purification beads are not included in this kit. If beads are required, we recommend ordering the NEBNext® Ultra™ II RNA Library Prep Kit for Illumina® (NEB #E7775).
Do you prefer to use non-strand-specific library prep methods, but need increased sensitivity and specificity from your RNA-seq experiments, from ever-decreasing amounts of input RNA? To address these challenges, our next generation of non-directional RNA library prep kit has been reformulated at each step, resulting in several fold higher yields of high quality libraries and enabling use of lower input amounts and fewer PCR cycles.
The Ultra II RNA Library Prep Kit for Illumina is designed for non-directional (non-strand-specific) RNA library construction, and delivers significantly increased sensitivity and specificity from your RNA-seq experiments, from ever-decreasing amounts of input RNA. In conjunction with ribosomal RNA (rRNA) depletion or poly(A) mRNA enrichment, the kit enables the production of high quality libraries from 5 ng or 10 ng of Total RNA, respectively, up to 1µg.
For use with NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1) (NEB #E7416), refer to the Protocols tab for UMI Adaptors-specific guidance.
LIBRARY YIELDS
Figure 1. NEBNext Ultra II RNA produces the highest yields, from a range of input amounts Poly(A)-containing mRNA was isolated from Human Universal Reference RNA (Agilent #740000) and libraries were prepared using the NEBNext Ultra II RNA Kit (plus the NEBNext Poly(A) mRNA Magnetic Isolation Module), and the Illumina TruSeq RNA Sample Preparation Kit v2. Input RNA and number of PCR cycles are indicated. Library yields from an average of three replicates are shown. View additional data on library yields
DUPLICATION RATES
Figure 2. NEBNext Ultra II RNA with NEBNext rRNA Depletion results in lower duplication rates . Ribosomal RNA was depleted from 1 μg, 100 ng and 5 ng of Human Universal Reference RNA (Agilent #740000) using the NEBNext rRNA Depletion Kit (Human/ Mouse/Rat) or Illumina Ribo-Zero™ Gold rRNA Removal Kit (Human/Mouse/Rat). Libraries were then prepared using the NEBNext Ultra II RNA Kit or the Illumina TruSeq RNA Library Prep Kit v2, respectively. 5 ng input was tested only with the NEBNext kits. Libraries were sequenced on an Illumina NextSeq® 500 using paired-end mode (2x76 bp). Reads were down sampled to 10 million read pairs and mapped to the hg19 reference genome. Duplication rates were calculated as a fraction of uniquely mapped reads using the ‘Read Duplication’ tool of RSeQC where reads mapping to the same genomic location are regarded as duplicated reads. View additional data on library quality
MAXIMIZING TRANSCRIPT COVERAGE
Figure 3. NEBNext Ultra II RNA libraries provide uniform coverage across the gene body of transcripts Poly(A)-containing mRNA was isolated from Human Universal Reference RNA (Agilent #740000), and libraries were prepared using the NEBNext Ultra II RNA Kit (plus the NEBNext Poly(A) mRNA Magnetic Isolation Module), and the Illumina TruSeq RNA Sample Preparation Kit v2. Input RNA amount is indicated. Libraries were sequenced on an Illumina® NextSeq® 500 using paired-end mode (2x76 bp). This view of the 5´ to 3´ coverage of RefSeq transcripts reveals consistent coverage for Ultra II RNA libraries as input RNA is decreased from 1 μg to 10 ng. The changes apparent in The TruSeq kit results from loss of coverage at the 3´ end of some transcripts. View additional data on transcript coverage
EXCELLENT LIBRARY COMPLEXITY AT LOW INPUT AMOUNTS
Figure 4. Low input NEBNext Ultra II RNA libraries retain complexity even at low input amounts Ribosomal RNA was depleted from 1 μg, 100 ng and 5 ng of Human Universal Reference RNA (Agilent #740000) with recommended amounts of ERCC RNA Spike-In Mix I (Thermo Fisher Scientific #4456740) using the NEBNext rRNA Depletion Kit (Human/Mouse/Rat) and libraries were then prepared using the NEBNext Ultra II RNA Kit. Libraries were sequenced on an Illumina NextSeq® 500 using paired-end mode (2x76 bp). Salmon 0.4.0 was used for read mapping and quantification of all ERCC transcripts. R2 values for linear fit are shown. TPM (Transcripts Per Kilobase Million) correlation analysis of the transcripts indicates excellent transcript expression correlation between the different inputs for Ultra II RNA libraries (A), including ERCC transcripts (B). View additional data on library complexity
Kit Components
The following reagents are supplied with this product:
Use this tool to find citations related to NEBNext products. Search by product, keyword or instrument name – use the filters to select specific product areas.
Additional Citations
Harcourt, J., et al. (2020) Severe Acute Respiratory Coronavirus 2 from patient with Coronavirus Disease, United States Emerg Infect Dis; 26 (2), 1266-1273. DOI: https://dx.doi.org/10.3201/eid2606.200516
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]
The Certificate of Analysis (COA) is a signed document that includes the storage temperature, expiration date and quality controls for an individual lot. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]_[Lot Number]
This product is covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB).
While NEB develops and validates its products for various applications, the use of this product may require the buyer to obtain additional third party intellectual property rights for certain applications.
For more information about commercial rights, please email us at busdev@neb.com.
This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.
Licenses
This product is licensed for research and commercial use from Bio-Rad Laboratories, Inc., under U.S. Pat. Nos. 6,627,424, 7,541,170, 7,670,808, 7,666,645, and corresponding patents in other countries. No rights are granted for use of the product for Digital PCR or real-time PCR applications, with the exception of quantification in Next Generation Sequencing workflows.
For additional information or to inquire about commercial use, please contact busdev@neb.com.
Trademarks
ILLUMINA®, TRUSEQ®, NEXTSEQ® and RIBO-ZERO® are registered trademarks of Illumina, Inc. AGILENT® is a registered trademark of Agilent Technologies SPRISELECT® and AMPURE® are registered trademarks of Beckman Coulter, Inc.
Based on your Freezer Program type, you are trying to add a product to your cart that is either not allowed or not allowed with the existing contents of your cart. Please review and update your order accordingly If you have any questions, please contact Customer Service at freezers@neb.com or 1-800-632-5227 x 8.
You have been idle for more than 20 minutes, for your security you have been logged out. Please sign back in to continue your session.
Institution Changed
Your profile has been mapped to an Institution, please sign back for your profile updates to be completed.
Sign in to your NEB account
To save your cart and view previous orders, sign in to your NEB account. Adding products to your cart without being signed in will result in a loss of your cart when you do sign in or leave the site.